Mask Particle Protection and Filtration Efficiency Tester

After-sales Service: Yes
Warranty: 1 Year
Display: Digital
Control: Manual Control
Weight: 0-100Kg
Power Source: AC220V
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Detailed Photos
Overview

Basic Info.

Model NO.
FTech-EN136-1
Standard
GB6096-2009
Transport Package
Plywood Case
Trademark
TESTech
Origin
China
HS Code
900490
Production Capacity
100

Product Description

The tester introduction
The mask particle protection effect and filtration efficiency tester is used for testing the protection effect and filtration efficiency of daily protective masks and respirators against particles. It is suitable for medical equipment testing center, safety protection testing center, labor protection testing center, drug testing center, disease prevention and control center, textile testing center, hospitals, mask and respirator manufacturers, etc.


Equipment use
Mask particle protection effect and filtration efficiency tester for daily protective masks and respirators on the particle protection effect and filtration efficiency test. Applicable to medical equipment inspection center, safety and protection inspection center, labor protection inspection center, drug inspection center, disease prevention and control center, textile testing center, hospitals, masks and respirators production enterprises, etc.

The main technical indicators
1,Adopt the cold generation aerosol generator to produce continuous and stable aerosol particles, and it is convenient to refill the solution. 
2,Adopt high precision PM2.5 sensor to measure the aerosol concentration. 
3,The whole process of particle leakage prevention design, to protect the safety of laboratory personnel. 
4,Compatible with mask and respirator type specimens to test the effect of particulate protection and filtration efficiency. 
5, aerosol generator 2 sets: salt particulate aerosol generator and oil particulate aerosol generator. 
6, equipped with aerosol particulate matter electrostatic charge neutralization device. 
7,Pneumatic clamps and equipped with protection devices, safe and convenient to use. 
8,Configuration of temperature and humidity sensor, real-time display of environmental temperature and humidity (temperature and humidity requirements: 25 ºC ± 5 ºC, 30% RH ± 10% RH). 
9,Configuration of glass rotor flow meter, vacuum pump, laser dust particle counter. 
10,Filtration efficiency detection range: 0-99.999%. 
11,Filtration efficiency detection flowmeter range (10-100) L/min, precision 2.5 grade. 
12,Filtration efficiency sampling frequency: 1-9999 times / min can be set arbitrarily. 
13, filtration efficiency particle concentration: (20-30) mg/m3; counting median diameter: salt particulate matter (0.075 ± 0.02) μm, oil particulate matter (0.185 ± 0.02) μm; particle size distribution geometric standard deviation: salt particulate matter ≤ 1.86, oil particulate matter ≤ 1.60; dynamic detection range (0.001-100) mg/m3, precision 1%. 
14,Protection effect test bin before the door design, good sealing, configuration of the operating gloves, convenient to be tested mask replacement. 
15,Protection effect test using standard head model: 1 standard head model, imitating the real situation of people wearing protective masks. 
16,Protection effect aerosol particulate matter: test bin concentration range (20-30) mg/m3, adjustable settings, concentration fluctuations of less than ± 10%; aerosol generator produces particle size distribution 0.02-2μm, mass median diameter: salt particulate matter 0.6μm, oil particulate matter 0.3μm. 
17, protective effect aerosol concentration detection device: gas sampling flow (1-2) L / min, sampling frequency: 20 times / min (1-9999 times / min can be set arbitrarily), dynamic detection (0.001-100) mg / m3, precision 1%. 
18, protection effect inhalation gas sampling tube in the nostrils directly under the end (in the mouth). 
19, protection effect using respiratory simulator, simulating the human respiratory state. 
20, breathing simulator: sinusoidal airflow, frequency 20 times / min, breathing flow control (30 ± 1) L / min, respirator flow range: 0-40 L / min. 
21,Apparatus accuracy level (accuracy level): 1 level 
22,Control system: computer control test process, automatic data collection, configuration of special computer and test software. 
23, computer automatic test and display: test bin media concentration, inhalation gas media concentration, background concentration; automatic calculation: filtration efficiency, protection effect; can save, output, query, print test data. 
24,Power supply: AC220V 50Hz    

Applicable standards. 
GB/T 32610-2016 Technical specification for daily protective masks 6.13 (Appendix A), 6.14 (Appendix B) 
GB 2626-2006 respiratory protective equipment-self-priming filtered anti-particulate respirator 
GB 19082-2009 Medical disposable protective clothing technical requirements 
GB 19083-2010 Technical requirements for medical protective masks 
YY 0469-2011 Medical surgical masks