This tester applies to test maximum and minimum concentration of flammable vapor or gas's under the condition of standard atmospheric pressureand set temperaturewith inert gases as diluent
Special reminders: not applicable to substances whose oxidability is stonger than air
Conforms to ASTM E681 (Standard Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases))
Parameters
Operating environment: 5~30 ºC,<85%RH
Test subjects : Gas or gasifiable solid, liquid
Working temperature range: -5~180ºC
Temperature control accuracy: ±1ºC
Sample temperature measurement accuracy: ±1ºC
Pressure measurement range: 0~110kPa
Pressure measurement accuracy: ±0.1%FS
Vacuum degree: ≤1.33kPa
Leakage Degree: ≤0.01kPa/min
Glass container for test: Spherical of volume 5L or 12L.
Electrical power: AC220~240, 13.5A
Dimensions: 930mm×600mm×1100mm
Weight: 160kg
Function characteristics
8 inch LCD touch panel, windows CE operating system, embedded software can set experimental conditions and control experiment.
Remote automatic ignition control can ensure the safety of experimenters.
The protective door with anti-fog double-layer tempered glass viewing window is easy for observation and the rear door for reducing pressure are both safe and reliable.
With dual interlock protection devices,when the door isn't closed or the temperature don't reach target temperature, the ignition operation doesn't work
The video monitoring system records the test process while playback can be checked to observe the result after the test.
Completeautomatic test processsupports parameter setting, data storage, view statements, and other functions.