• Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666
  • Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666
  • Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666
  • Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666

Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666

After-sales Service: Yes
Warranty: 1 Year
Type: Fire Test Machine
Accuracy Grade: 1
Display: Touch Screen
Control: Computer Control
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
FTech-UL 1666
Weight
100-500Kg
Power Source
AC220V
Standard
UL 1666
Pressure Gauge
U-Type
Hygrometer
Measuring Chamber Temperature and Humidity
The Wall Structure
Density of 106lb / FT3 (1698kd / M3) of Concrete
Transport Package
Plywood Case
Specification
7.12M High X1.3M Wide X2.5M Long
Trademark
TESTech
Origin
China
HS Code
90318090
Production Capacity
100

Product Description

Product Description

Testech shaft space cable combustion test equipment combined with test box, burners, smoke pipe, control cabinets, gas control system, exhaust control system, temperature acquisition system and data acquisition and processing systems and user operating systems; the test system is used in the installation of poles or vertically through the height of the ground floor of the wires and optical fibres of the flame height value and thus test the cable combustion level; the purpose of this test is to detect The purpose of the test is to determine whether the flame combustion characteristics of the uplift wires comply with the requirements of the National Electrical Code. The test is not intended to detect toxicity or corrosiveness by combustion or decomposition.

Model: FTech-UL 1666 

Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666


Testing Standards                                   
UL1666, ANSI/ASTM D 5207 & UL 1581, ANSI/ASTM D 5025
UL1666<<Test for flame propagation height of electrical and optical-fiber cables installed vertically in shafts>>
 
Parameters                                      
1. U-type pressure gauge: measuring chamber pressure maintained at 0-12PA;
 
2. Hygrometer: measuring chamber temperature and humidity;
 
3. The structure of the chamber: the overall structure of the concrete wall by the brick, the first layer is 1.22M, the second layer is 3.66M, the top is 2.24M. External dimensions: 7.12M high x1.3M wide x2.5M long;
 
4. The wall structure is a density of 106lb / ft3 (1698kd / m3) of concrete, the thermal conductivity (k) at 21.1 ºC for the 0.38Btu (0.055W / mk);
 
5. The first and second layer by the 203mm thick ordinary weight of the cement composition.Roof is made of wall to ensure its tightness;
 
6. The measuring hole in the second layer must be above the vertical hole of the first layer measuring hole (305mm by 610mm), each hole is 203mm behind the box and 102mm from the side of the box
Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666



 

Detailed Photos

Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666

Cable Installed Vertically in Shafts Fire Testing Machine with UL 1666

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now