Single Burning Items BS EN 13823
Introduction
SBI was measured supplies (excluding floorings) performance at a single burning heat invasion conditions.
Samples were placed inside the sliding flame (methane combustion sandbox boxes), under the exhaust pipe.
Sample combustion reaction condition to accept dual monitor machine and visually. Heat and smoke
release rate assessment instruments detect objects by observing performance.
The sample is placed on a mobile cart located in the exhaust system under the combustion reaction of the
sample can be automatically displayed and visible. By calculating the heat release rate (HRR), smoke
release rate (SRR) to evaluate the combustion characteristics of the machinery, and other physical
properties evaluated by visual observation. SBI measurement range, the fire growth rate index (FIGRA) is
the most representative measure factors; in addition, there are factors measuring oxygen consumption
representative, CO/CO2 generation amount, smoke growth rate index (SMOGRA) and so on. Maximum
heat release rate can reach 1MW.
Model: FTech-EN13823
Standard
• BS EN 13823
Features:
1, Equipment with combustion chamber, small cart, smoke pipes, gas supply systems, control systems and
data processing systems;
2, Chamber dimensions: 3m*3m*2.4m, the wall is composed of stainless steel and calcium silicate board.
3, Internal fixtures are made of stainless steel.
4, J-smoke insulation pipe for piping diameter 315mm ± 5mm, 50mm thick heat-resistant mineral wool
insulation;
5, The cart has a main burner and an auxiliary burner, the size of which is an isosceles triangle with a side
length of 250 mm.
6, The density of calcium silicate plate is 800±150 kg/m³ and the thickness is 12±3mm.
7, Smoke extraction capacity: 0.50m3/s~0.65 m3/s;
8,The range of the imported pressure sensor is 0~100pa, the precision is ±2pa, and the response time of
90% of the output of the sensor is up to 1 s.
Burning system
1, 10kV spark igniters, ceasefire with security devices. Igniter location through a lever connected to the
closing mechanism;
2,The mass flowmeter imported from Japan controls the input flow with a range of 0 g/s~2.3 g/s and
a reading accuracy of 1%.
3, Double gas valve control system fault causing the system to avoid electromagnetic valve leak, resulting
in a risk of explosion;
4, Two produced in accordance with standard stainless steel; thickness 1.5mm litter box burner;
5, Rectangular shield plate: width (370±5) mm, height 550mm ± 5mm, made from calcium silicate Board;
6, Imported Mass Flow Controller; Range 0g/s~2.3g/s; Accuracy of reading in 0.6g/s~2.3g/s is 1%.
7, Automatic switching of main burner and auxiliary burner by gas supply switch.
8,Exhaust rate (0.6±0.05)m³/s.
9, Flame detection, system will shut off gas valve once flame out.
Gas sampling system
1 .High precision patented sampling system ensures that the sampled gas entering the gas analyzer is stable
and free of impurity interference, and makes the analysis result of the analyzer more accurate.
2, Including particulate filter; three-stage filtering system; filtering accuracy 0.5um;
3, Cold traps: principle of compressor refrigeration system, gas sampling temperature control 0~5ºC;
4, Suction pump imported from German: flow rate: 33L/min, vacuum: 700 mm Hg, pressure: 2.5 bar
5, Drying barrel: drying and impurity removal of oxygen and nitrogen dioxide analysis gas paths.
6, High-precision ball valves; opening and closing of gas paths.
7, Mass flow controller imported from Japan;
Parameters
1, Oxygen-concentration analysis: imported Imported paramagnetic oxygen sensor, O2 measurement range
0-25%, linear deviation < 1%. Oxygen Analyzer response time less than 12s; Analyzer output maximum
resolution 100X10 -6 ;
2, CO2 Analysis: infrared CO2 Analyzer, CO2 measurement range: 0-2/10%, linear deviation: <±1%.
Analyser response time less than 12s; Analyzer output maximum resolution 100X10 -6 ;
3, Smoke density was measured by incandescent light system with color temperature of 2900 ± 100K,
current fluctuation range of ±0.5%, linear output of smoke density, time compensation function, and smoke
density was measured by imported photovoltaic cell module.
4.Transmittance calibration mode: one-button 5-level automatic calibration system with imported filters; no
need to replace filters manually.
5, Detector; spectral distribution corresponds to CIE; chromaticity standard function accuracy is ±5%;
output linearity is within 3% of transmittance or 1% of absolute transmittance;
6, The system response time no more than 3s;
7, Three K-type armored thermocouples imported from the USA with a diameter of 0.5mm and a
temperature accuracy of 0.5 C.
8, The range of pressure sensor imported from USA is 0-100Pa, the precision is ±2pa, The response
time of pressure sensor output is less than 1s.
9, Smoke exhaust capacity is 0~0.65m³/s; hemispherical probe measures smoke pipe wind speed
accurately .
10, Other thermocouples are 2mm K armored thermocouples;This Information carrier and the information it contains are the property of TESTech Instrument. Any
11.Precision of ambient pressure ±200Pa;
12,Minimum system recording time 3S;
13, The accuracy of system time record is 0.1s
Computer Control System
1.Standard Control Cabinet, Computer+Labview Intelligent Control System
• System modular design:system configuration, calibration, testing, diagnosis, reporting and other
functional modules;
• Setting and displaying of control parameters; displaying and inquiring of test status and faults.
• Data parameters are displayed in the form of numbers and curves, which is convenient for observation and
trend judgment.
• The data acquisition and preservation; picture monitoring, real-time temperature curve, real-time CO2 / O2
data curve display; the historical trend and data query;
• The original data and test results are stored in Excel format
• Report module provides data preview, query, revision, report export functions
2.It has the functions of sound alarm and accident alarm.
3.The control box has USB/RS232 serial port, which can be connected with computer .
4.PLC Control System:
• Automatic ignition, ignition failure detection and protection.
• Automatic control and display of propane gas flow.
• PLC + frequency converter implements automatic control and display of exhaust gas flow.
• Automatic measurement and calculation of material combustion: heat release rate (H.R.R), smoke
production rate (SPR), oxygen consumption , CO2 production
5,In order to reduce the error caused by the transmission distance of analog signals, the independent
acquisition box module is used to collect the data of test section. The acquisition box communicates with
the main control box by MODBUS to ensure the accurate transmission of acquisition signals.
6.The test report can realize the switching analysis of complete graph and thumbnail.
7.Free choice of data curve: O2, CO2/CO, temperature, wind speed, etc.
8,The signal acquisition and processing module links with the air volume circuit control module,
intelligently adjusts the preset wind speed through the logic calculation of the programmable controller, and
the mechanical rotation module links with the I/O port of the programmable controller to control the closed
state of the rotating mechanism.
• Labview software with advantages of friendly interface, powerful data interaction, more suitable for
research and analysis
• Software modular design can independently analyze the process curve of each test data.
• Through parameter setting, the original data in the test can be revised, and the difference of the test results
of the same sample can be compared. It can help customers to analyze the influencing factors of the test.This Information carrier and the information it
Specification:
Max power: |
3.5KW |
Chamber dimension: |
3000mmx3000mmx2000mm (L*W *H) |
Dimension of exhaust pipe:
|
5200mmx3000mmx4300mm (L*W *H) |
Control cabinet dimension: |
800mmx800mmx2030mm (L*W *H) |