Medical Mask Flame Retardant Performance Tester with En 136

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
3074 square meters
Terms of Payment
LC, T/T
  • Medical Mask Flame Retardant Performance Tester with En 136
  • Medical Mask Flame Retardant Performance Tester with En 136
  • Medical Mask Flame Retardant Performance Tester with En 136
  • Medical Mask Flame Retardant Performance Tester with En 136
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Applicable standards
  • After Sales Service
  • FAQ
Overview

Basic Info.

Model NO.
FTech-EN136-3
Type
Material Testing Machine
Maxcapacity
No
Accuracy Grade
No
Load Way
No
Loading Method
No
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Standard
GB 2626-2006 GB 2890-2009
Metal Head Mold Wall Thickness
2 ~ 3mm
The Flame Height
From The Top of The Burner for (20 ± 2) mm
Brand
Testech
Delivery
by Sea
Material
Iron
Transport Package
Plywood Case
Trademark
TESTech
Origin
China
HS Code
900490
Production Capacity
100

Product Description

Product Description

Medical mask flame retardant performance tester is mainly used to dry test protective masks, gas masks, etc. with a certain degree of line bundle contact flame combustion performance, is a mask products flame retardant performance of special testing instruments.

Medical mask flame retardant performance tester application
Mainly used to test the burning performance of protective masks, gas masks, etc. after contacting the flame at a certain linear speed, is a special test instrument for the flame retardant performance of mask products.

Medical Mask Flame Retardant Performance Tester with En 136

Medical Mask Flame Retardant Performance Tester with En 136
Medical Mask Flame Retardant Performance Tester with En 136

Product Parameters

1, mask fixture for metal head mold, can simulate the use of the mask state. 
2,The burner is equipped with combustible gas interface such as propane (liquefied gas). Handheld electronic pulse iigniter, easy to iignite. 
3,In accordance with the height of the full facemask, the distance between the full facemask and the burner has been adjusted before the instrument leaves the factory. 
4,Other types of masks can be adjusted by replacing the burner parts to achieve the test distance. 
5,The burner is automatically positioned at regular intervals, and the flame height and flame temperature are calibrated at the iignition position. 
6,Burning time and shade combustion time are automatically recorded and digitally displayed. 
7, equipped with flame temperature thermocouple measuring probe, flame temperature display. 
8, flame height scale and flame temperature probe can be turned horizontally and move up and down to meet the measurement requirements with the burner height adjustment. 
9,The horizontal movement line speed of the tip of the nose of the head mold is (60±5)mm/s, and the head mold can be rotated in the vertical plane. 
10, flame height can be adjusted (standard requirements 40 ± 4mm) 
11, flame temperature thermocouple measuring probe diameter of 1.5mm 
12, the flame in the height from the top of the burner for (20 ± 2) mm at the temperature of (800 ± 50) ºC 
13, metal head mold wall thickness of 2 ~ 3mm, flame resistance and combustion resistance 
14, continued to burn time and negative combustion time timer: 0 ~ 99.99 seconds, accuracy: ± 0.01 seconds 
15, working power: AC220V, 50Hz, 50W 
16,Weight: about 30kg. 
17,User's own equipment: one tank of propane gas 

 

Applicable standards


GB 2626-2006 respiratory protection self-absorbing filtered anti-particulate respirator 
GB 2890-2009 respiratory protection self-absorbing filtered gas mask 
GB 21976.7-2012 Building fire escape and evacuation equipment Part 7: Filtered firefighting self-rescue breathing apparatus
BS EN 136 "Respiratory protective devices-Full face masks-Requirements,testing,marking" 8.5.1 Class 1 full face masks

After Sales Service

1.  When get official order, equipment layout drawing and confirmation
2. Remote video training, installation guiding, trubleshooting by free. 
3. On site training, installation guiding, all charges training fee+ traffic, hotel, board and lodging, Visa which provided by customer or paying.
4. 1 year warranty
5. Permanent software updated. 

 

FAQ

1.What's the delivery time?
About 3~4months.

2.What's your guarantee terms?
The warranty of all products is 1 year. And we can supply life-long technical support. 

3.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary.