Vertical Tray Fire Test Apparatus with UL1685

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
3074 square meters
Terms of Payment
LC, T/T
  • Vertical Tray Fire Test Apparatus with UL1685
  • Vertical Tray Fire Test Apparatus with UL1685
  • Vertical Tray Fire Test Apparatus with UL1685
  • Vertical Tray Fire Test Apparatus with UL1685
  • Vertical Tray Fire Test Apparatus with UL1685
  • Vertical Tray Fire Test Apparatus with UL1685
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • After Sales Service
  • FAQ
Overview

Basic Info.

Model NO.
FTech-UL1685
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Exhaust
0.63~0.67m2/S( Measuring), Minimum 100m2 / Min (Ex
Cable Bracket Size
300mmx76mmx2400mm
Transport Package
Plywood Package
Trademark
TESTech
Origin
China
HS Code
90248000
Production Capacity
100

Product Description

Product Description

This apparatus is based on IEEE1202 and IEEE 383 standard design and development. TESTECH UL 1685 Resistance Assemblies Tester is used to assess single or bunched cables under defined conditions inhibit the spread of flame apparatus ability to meet UL 1685, IEEE 383 and IEEE 1202's testing requirements. UL flame contact test is a vertical flame test stand, when the cable is subjected to shock and burning fire source, the cable damage height and decided to test the value of smoke emission. We meet the UL testing procedures cable is accepted this device can be used to evaluate the assessment of single cable or multicore cable flame spread situation. In this device can also increase gas analysis HRR (heat release rate), smoke density and other means for analyzing the test material.

Model:FTech-UL1685

Vertical Tray Fire Test Apparatus with UL1685


Standard:
 • UL1685
• IEEE 1202
- Flame propagation - Wire and cable test
• IEEE 383
IE-level nuclear power cables, field connectors and connector type test standard
 Main Features
1, The test box size is 2,600 (W) x 2,600 (D) x 3,100 (H) mm, the volume is 20.28m3, internal area is 6.76m2.
2, The internal toolings are all made of stainless steel;
3, The combustion test box structure with a smoke discharge hole, there are the fresh air intake;
4, The test room walls made of concrete bricks or refractory bricks. Walls have observation window;
5, The test room containing an access gate made from steel material;
6, Two-way differential pressure sensor measuring flue gas flow rate; and import pressure sensors, pressure precision 0.025pa;
7, K-type thermocouple (Inconel) detects the temperature of the flue;
8, Cable bracket size:(300mmx76mmx2400mm);
9, The burner is formed by the ribbon propane torch and inport wick;
10, Propane flow meter: at standard temperature and pressure (20 ° C, 101 kPa) at (220 ± 8 cm3 / s);
11, Air flow meter: at standard temperature and pressure (20 ° C, 101 kPa) at (1280 ± 80 cm3 / s);
12, Thermocouple and bi-directional wind speed, which installed in the exhaust pipe, can measure exhaust temperature and gas flow rate;
13, Tray size is 305 (length) × 76 (width) × 2438 (height) mm, ladders horizontal width of 25 ± 6mm, spanning a 229mm;
14, Ribbon propane burner with a mixer Ventury, which meet IEC60332-3;
15, Using the data acquisition board, accurately capture and measure the internal component temperatures and burner flame temperature;
16, Solenoid valve and ignition by button on the control panel manual control, emergency situations can turn off the power to the instrument (not including PC power supply);
Smoke density systems:
 1, The smoke density analysis: beam clear shot automatic lighting system measures the smoke density; color temperature is of 2900 ± 100K, current fluctuation range of ± 0.5%; smoke density linear output with time compensation;.
 2, Together into a 20mm lens parallel light beam; d / f <0.04;
 3, The detector, spectral distribution corresponding to the degree consistent with CIE; color standard functions precision ± 5%; less than 1% output linearity within 3% transmittance or absolute light transmittance;
Measuring System:
1, Digital data acquisition system is used to collect and record smoke density and pressure measurement. The speed and capacity of the system is to collect data from every 5 seconds.
2, To ensure that the nominal gas flow in the pipe line is 0.65 ± 0.05 cubic meters / second.
3, Computer control system, labview software; beautiful interface, easy to operate;
 
Product Parameters
 
Model TTech-UL1685
Size Internal cabinet dimensions: 2,600(W)×2,600(D)×3,100(H)mm
Console Size 600(W)×750(D)×1600(H)mm
Power AC 220V, 50/60Hz, 15A
Weight Approx. 500kg(chamber), Approx. 130kg(control)
Instructions Available
Exhaust 0.63~0.67m2/s( Measuring), Minimum 100m2 / min (extraction)
Tool gases, personal computers, vacuum cleaners, propane gas

 
After Sales Service

1. When get official order, equipment layout drawing and confirmation
2. Remote video training, installation guiding, trubleshooting by free. 
3. On site training, installation guiding, all charges training fee+ traffic, hotel, board and lodging, Visa which provided by customer or paying.
4. 1 year warranty
5. Permanent software updated

 

FAQ

1.What's the delivery time?
About 2~3months.

2.What's your guarantee terms?
The warranty of all products is 1 year. And we can supply life-long technical support. 

3.Can you supply training?
We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary.


 
 

 
 
 
 
 
 
 
  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier