Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2017

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
3074 square meters
Terms of Payment
LC, T/T
  • Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633
  • Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633
  • Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633
  • Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633
  • Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633
  • Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633
Find Similar Products

Basic Info.

Model NO.
FTech-CFR 1633
Weight
100-500Kg
Power Source
AC220V
Standards
16 Crf 1633
Manual
Supplied
Control Cabinet
19 Inch Standard Cabinet
Smoke Exhaust Capacity of Fan
Not Less Than 0.5m³/S
Transport Package
Plywood Package
Trademark
TESTech
Origin
China
HS Code
90318090
Production Capacity
100

Product Description

Model:FTech-CFR 1633
Standards:16 CRF 1633
Flammability (Open Flame) of Mattress Sets Test Apparatus With16 Crf 1633

Introduction:

Testing room: Testing room can be built as closed or open.
Closed test room:(Option:CFR 1633 standard requires test room can be built as closed or open.)
The room is made of rock wool board. There are no openings except door and video surveillance windows.
The size of the test room is 3660 ± 25mm in length, 3050 ± 25mm in width and 2438 ±25mm in height.
The door is 2032 ± 6 mm high and 965 ± 6 mm wide.
Quartz glass monitor window, size 150x150mm.
The smoke collecting hood is located outside the door (smoke outlet) to collect smoke.
Open test room
The smoke collecting hood is positioned directly above the sample and the bottom edge is 2400 mm away from the ground.
Conical collector size: 3000mm X 3000mm, height 1000mm
The conical collector has 900mm X 900mm X 900mm X 900mm cubic mixing chamber on the top, and the mixer is installed inside.
The smoke exhaust pipe consists of a diversion section (x2), a straight section, a measuring section and a fan.
The measuring section is equipped with wind speed probe, thermocouple, optical system and sampler.
Smoke exhaust capacity of fan is not less than 0.5m³/s
Control cabinet
19 inch standard cabinet, simple appearance, science and technology
Control system center, integrated computer, display, analyzer, cold trap, control and data acquisition system.
19 inch display, Labview control software, electronic control and pneumatic configuration panel.
Computer: CPU I3, memory 4G, hard disk 500G Win7/Win10 system
Equipped with imported analyzer (domestic analyzer is optional)
Measurement of Gas Concentration of O2, CO2 and CO.




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier