Main purpose
This equipment is developed according to the new national standard GB/T2812-2006 "Safety helmet test method", and is used for pretreatment of UV irradiation before the safety helmet test.
The instrument features
1,Microcomputer automatic control
2,Opening doors on both sides for quick installation of specimens.
3, using WXWOB-450 short pulse high pressure xenon lamp, and configured with a special trigger
4,Micro-computer with automatic time accumulation function
5,Timing range: 0-999 hours. When the test time reaches the set time, the system has an automatic power-off function
6, built-in over-temperature protection system and light sensor
7, when the cooling system stops working, the xenon lamp has an automatic protection function.
8,Safety cap distance from the lamp: 150mm.
The main technical indicators
1, high-quality cold-rolled plate electric control box
2, using high-precision temperature control instrument.
3,Timing range: 0-999 hours
4,Number of pre-treated helmets: 1-14
5, ultraviolet radiation source: high-pressure long-arc xenon lamp, 220V, 450W
Conformity with the standard
GB/T2811-2007 safety helmet
GB/T2812-2006 Safety helmet test method